Skip to main content

Vizio SmartCast TV

The Vizio driver controls SmartCast TVs through the local HTTPS API with a PIN-pair handshake that mints a long-lived bearer token. One GEM device represents one TV.

Status​

PIN pairing, power, volume, mute, current-input read/write, navigation keys, and raw key passthrough are implemented. Picture-mode and audio-mode setpoints, app launching ("Cast to Netflix"), and on-screen content metadata are out of scope for this driver — use the TV remote or the SmartCast mobile app for those.

Prerequisites​

  • SmartCast TV (2016+) with Power Mode = Quick Start enabled in the TV settings — Eco mode powers down the API when the screen is off.
  • Static IP or DHCP reservation on the TV.
  • Physical access to the TV during initial pairing — a 4-digit PIN displays on-screen.
  • TCP 7345 (older firmware) or 9000 (newer SmartCast) reachable from the GEM host.

Setup​

  1. Reserve the TV's IP in DHCP.
  2. In System > Devices, create a device with driver vizio_smartcast. Set:
    • ip — TV IP
    • port — 7345 (older) or 9000 (newer)
    • Leave auth_token blank for now.
  3. Turn the TV on. From the Script Console run:
    await gem.command({device_id: <device_id>, command: 'pair_start'});
    The TV will display a 4-digit PIN.
  4. Within the pairing window, run:
    await gem.command({device_id: <device_id>, command: 'pair_finish', args: {pin: '1234'}});
    On success the response is {status: 'paired', message: 'auth_token saved.'}. The bearer token is stored encrypted as the auth_token attribute and the driver re-authenticates automatically.
  5. Verify:
    await gem.command({device_id: <device_id>, command: 'get_power'});
    await gem.command({device_id: <device_id>, command: 'get_current_input'});

If pair_start returns 404, the TV is on the other port — flip port between 7345 and 9000 and retry.

Attribute reference​

Device attributes​

AttributeTypeRequiredDescription
ipstringyesTV LAN IP.
auth_tokenstring (secure)for controlBearer token returned by pair_finish. Sent as the AUTH request header.
portintno7345 (older) or 9000 (newer SmartCast). Default 7345.
device_idstringnoIdentifier the TV stores against the issued token. Defaults to gem-<device id>.
device_namestringnoFriendly name shown in the TV pairing list. Default GEM Controller.
status_intervalintnoPoll interval in milliseconds. Default 10000.

The driver reflects the following attributes onto the device:

AttributeTypeSource
power_statestringon / off from /state/device/power_mode/.
current_inputstringHDMI-1, HDMI-2, CAST, SMARTCAST, etc.
volumeint0-100.

Zone address format​

This driver does not use zones — each TV is its own device.

Commands​

CommandArgsNotes
power_on / power_off / power_toggle—Power keypress.
volume_up / volume_down—
volumelevel (0-100)Absolute set via MODIFY+HASHVAL on /menu_native/dynamic/tv_settings/audio/volume.
mute_on / mute_off / mute_toggle—
get_inputs—Returns the full input list — pass the NAME field to set_input.
get_current_input—
set_inputinputExact input NAME (case-sensitive, e.g. HDMI-1).
navkeyOne of up, down, left, right, ok, back, exit, menu, info.
send_keycodeset, codeRaw KEYPRESS for codes not exposed above.
pair_start / pair_finish / pair_cancelpin (finish)Pairing flow — see Setup.

Known limitations​

  • App launching (Netflix, YouTube, etc.) requires the deeper SmartCast app catalog API which Vizio has rotated multiple times — not implemented.
  • Picture/audio preset setpoints are reachable via raw send_key but no convenience commands are wrapped.
  • Re-pairing produces a fresh auth_token; old tokens stop working silently. Plan to re-run the pair flow if you ever factory-reset the TV.

Troubleshooting​

SymptomCheck
pair_start returns 404Wrong port. Flip port between 7345 and 9000 and retry.
401 or empty responses on commandsauth_token was rotated. Re-run pair_start + pair_finish.
Power state always reads offTV is in Eco power mode; switch to Quick Start so the API stays reachable when the screen is off.
set_input does nothingRun get_inputs and pass the exact NAME (case-sensitive, hyphen-separated, e.g. HDMI-1).
Volume command returns {error: 'failed to read current volume'}The TV needs an authenticated GET to mint a fresh HASHVAL — confirm auth_token is set and not stale.