Configuration reference

Use Settings for normal administration. The installed service reads environment configuration from /etc/evernvr/evernvr.env; changes require a service restart and therefore a planned recording gap. A source checkout can set variables in the process environment.

VariablePurpose
PORTListener port, HTTPS with plain HTTP redirected; default 3099
EVERNVR_BINDListening address; the installer writes the selected LAN address. Unset listens on every interface
EVERNVR_INTERFACENetwork interface to listen on instead, such as eno1, written by the installer's --interface. The recorder takes the interface's IPv4 address, or a global IPv6 one when it has no IPv4, checks it every 10 seconds, and moves the listener when it changes. It listens on 127.0.0.1 if the interface has no address at startup. Overrides EVERNVR_BIND
EVERNVR_DATADatabase, key, settings, and default media directory; production uses /var/lib/evernvr
EVERNVR_MEDIAInitial media directory; a saved storage selection takes precedence
EVERNVR_PUBLIC_ORIGINBrowser-facing origin for links; otherwise use the saved recorder address
EVERNVR_TLS_CERTPEM certificate chain from the site's own CA, in place of the recorder's own; pair with the key
EVERNVR_TLS_KEYMatching unencrypted PEM private key; pair with the certificate
EVERNVR_TLS=0Serve plain HTTP only, for development
EVERNVR_MDNS=0Disable service advertising: the _http._tcp (or _https._tcp) service browsers find, and the _evernvr._tcp service the mobile app looks for
EVERNVR_TZTime zone the recorder writes and schedules in, and sets on its cameras; defaults to the host's
EVERNVR_NTP=0Do not serve NTP to cameras on UDP port 123. Cameras are then not pointed at the recorder for their time; the regular clock checks still correct them
EVERNVR_PYTHONAbsolute path to an existing detector Python interpreter
EVERNVR_DETECT_BACKENDauto, onnx, or hailo; a saved preference wins
EVERNVR_DETECT_MODELModel under models/; default damoyolo_tinynasL20_T
EVERNVR_DETECT_FPSDetections per second per camera, site-wide; default 5
EVERNVR_SEMANTIC=0Disable local semantic processing
EVERNVR_RECOGNITION=0Disable local face and plate recognition, whatever Settings → Recognition says
EVERNVR_LOG_LEVELLowest level written to the recorder log: debug, info, warn, error
EVERNVR_BACKUP_BUDGET_GBSize the default backup folder on the system disk is kept within, nightly backups and pre-migration snapshots together; default 4. A backup folder on a NAS or second drive is bounded by its count alone

EVERNVR_DETECT_FPS is the lever for fitting more cameras onto one accelerator; see detection capacity before changing it. Set the recorder's zone under Settings → This recorder → Recorder clock; EVERNVR_TZ is only needed to pin a zone that differs from the host's. Schedules, reports, and the timeline all follow it, and while it is set a zone chosen in Settings changes the host's zone but not the one the recorder writes in.

Setting only one TLS path or using a mismatched certificate and key prevents startup. An expired certificate is served with a health warning so recording can continue; replace it and restart promptly.

Notification services​

Environment-provided service settings appear read-only in the UI and override stored values. Prefer the UI unless the deployment manages these centrally.

ServiceVariables
SMTPEVERNVR_SMTP_HOST, EVERNVR_SMTP_PORT, EVERNVR_SMTP_FROM, EVERNVR_SMTP_USER, EVERNVR_SMTP_PASSWORD
TelnyxEVERNVR_TELNYX_FROM, EVERNVR_TELNYX_API_KEY

Push has no settings. EVERNVR_NTFY_ORIGIN and EVERNVR_NTFY_TOKEN from earlier releases are ignored and can be removed.

Do not put real keys, camera passwords, recipient addresses, or host environment files into source control. See notifications for transport requirements and tests.

Installed paths​

PathContents
/opt/evernvr/currentThe running release and its maintenance tool (a link into /opt/evernvr/releases)
/opt/evernvr/previousThe previous release, kept for rollback
/opt/evernvr/backupsBackups taken before each update
/opt/evernvr/state/update-status.jsonProgress and result of the last update
/opt/evernvr-venvDetector environments; release-VERSION links to each release's
/var/lib/evernvrRecorder state and default media
/var/lib/evernvr/backupsDefault configuration backup location
/var/lib/evernvr/updatesDownloaded releases and the recorder's identity with the release server
/etc/evernvr/evernvr.envService environment; updates leave it alone
/etc/evernvr/keyring.jsonKeys trusted to sign releases
/etc/evernvr/disks.jsonPhysical devices included in disk-health checks
/var/log/evernvrInstall, update, rollback and adoption logs
/usr/local/sbin/evernvr-updateHost tool: apply, verify, status, rollback